Modutec 2000 Series Digital Panel Meters

You need flexibility. We provide it. We customize our meters to meet your specifications.

Additional Information

Weight 2 oz
Dimensions .99 × 3.78 × 1.89 in
Features

• Scalable in engineering units
• Custom labels for special readouts
• User Selectable functions, decimal point, offset, span, process voltage or current, DC voltage
• Red or green backlit display
• Splash and hose proof meeting NEMA 4, NEMA 12, and IPC 55 standards
• Resistant to damage with a high impact polycarbonate case
• Wide operating temperature ranging from -4°F to +140°F (-20°C to +60°C)
• 1/8 DIN industry-standard cut-out and 1-inch depth
• Screw terminals
• Over range indication
• Low cost
• The MODUTEC 2100 includes user-friendly dipswitch selection features

Applications

• Telecommunications
• Water Purification
• Sewage Treatment
• Flow
• Process
• Desalinization
• Temperature
• AC & DC Amps
• AC & DC Volts

FCC Compliance

Complies with the class B Limits of FCC rules and regulations, part 15, sub part J for conducted and radiated emissions.

Performance Specifications

Display

Digits3½ digits, 7 segments Backlit LCD (1999)
PolarityAutomatic (-) displayed
OverloadThree lower digits blank for readings greater than 1999
Digit Height0.5" (12.7 mm)
Decimal PointThree positions, external selection

Performance

Conversion Rate2.5 per second
Normal Mode Rejection≥40db 50-60Hz
Common Mode Rejection≥100db 50-60Hz (except isolated DC powered which is ≥80db 50-60Hz)
Zero AdjustAutomatic
Tempco±200PPM/°C typical (except thermocouple inputs which are .1°/degree zero tempco for selectable process ranges is only ±.2 count/°C)
Warmup10 minutes

Environment

Operating-20 to +60°C
Storage-30 to +70°C

Power Options

115V +10%, -15% 50 to 400Hz at 2VA
230V +10%, -15%50 to 400Hz at 2VA
10 to 28VDC150mA (including backlighting)
10 to 15VDC or 20 to 32VDC150mA (including backlighting)

DC Inputs

DC InputsAccuracyInput ResistanceOverload Protection
200mVDC & 2VDC±(.1% +1 count) typical
±(.2% +1 count) maximum
≥100 MΩ200V continuous
300V intermittent
20VDC & 200VDC±(.1% +1 count) typical
±(.2% +1 count) maximum
1 MΩ350V continuous
500V intermittent
DC Current±(.1% +1 count) typical
±(.2% +1 count) maximum
200mV drop full scale3 times f.s. current
Universal Selectable Process±(.1% +2 counts)4 to 20mA
10Ω ≥200mV
≥200KΩ 2V and up
≥1 MΩ
4-20mA: ±100mA
Voltage: 200V continuous, 300V intermittent

AC Inputs

AC InputsAccuracyInput ResistanceOverload Protection
AC Voltage±(.5% +1 count) 1 MΩ350V continuous
500V intermittent
5A AC Current±(.5% +1 count)Current transformer3 times f.s. current
50A AC Current±(.5% +5 count) typicalCurrent transformer3 times f.s. current

Frequency Inputs

Frequency InputsAccuracyDistortion
40.0 to 199.9Hz±.2Hz (40 to 70Hz)
±.5Hz (above 70Hz)
≤.1Hz for up to 20% third harmonic distortion
40 to 440Hz±1Hz ≤.1Hz for up to 20% third harmonic distortion

Temperature Inputs

TemperatureInputsAccuracyInput ResistanceOverload Protection
Type J Thermocouple
-23°C to +649°C±(.1% +1 count) accuracy
±1.3°C conformity error
45 uV maximum per 100&ohms; thermocouple lead resistance200V continuous
Type K Thermocouple
-40°C to +815°C±(.1% +1 count) accuracy
±1.2°C conformity error
45 uV maximum per 100&ohms; thermocouple lead resistance200V continuous
Type T Thermocouple
-73°C to +315°C±(.1% +1 count) accuracy
±1.5°C conformity error
45 uV maximum per 100Ω thermocouple lead resistance200V continuous
100 Ω Pt. ∝=.00385
-129 to +315°C
±(.2% + 1 count) maximum1mA RTD current±5V
100 Ω Pt. ∝=.00385
-73to +98°C
±(.2% + 1 count) maximum1mA RTD current±5V

Downloads

Datasheet

How To Order

Please refer to the Datasheet in the Downloads section of this page.

Click outside to hide the comparison bar