eDXI-100/200 Single or Dual Axis Digital Inclinometer

The Jewell eDXI-100/200 Series is a single or dual digital inclinometer with the convenience of Ethernet output. It offers connectivity via Power over Ethernet (PoE injector required), with Telnet being the standard communication protocol.

 

 

Additional Information

Weight 13.8 oz
Dimensions 3.75 × 2.88 × 3.63 in
Features

• Digital output
• Resolution 0.001°
• Mechanical Shock 1500g 1msec 1/2 sine
• Industry Standard Ethernet 10 Base T or 100 Base TX (Auto-sensing)
• For use in high shock and vibration environments
• PoE (power over Ethernet)
• Low Noise

Applications

• Radar/Antenna Control
• Structural Monitoring
• Linear Acceleration/Deceleration Measuring
• Automatic Train Control (ATC, ATP)

Performance Specifications

Static/Dynamic

Input Range (°)±1.0 ±3.0 ±14.5 ±30.0 ±60.0
Non-linearity (%FRO max)20.020.0150.020.020.03
Scale Factor Tolerance (% maximum)0.10.10.10.10.1
Scale Factor Temperature Sensitivity (PPM/°C maximum)100100100100100
Output at 0° Tilt (° max)±0.01 ±0.01 ±0.05 ±0.05 ±0.05
0° Output Temperature Sensitivity (°/°C, maximum)0.0050.0050.0050.0050.005
Bandwidth (-3dB, Hz, nominal)336303030
Transverse Axis Misalignment (° maximum)0.150.150.50.50.5
Resolution & Threshold (° maximum)0.0010.0010.0010.0010.001
Power on Repeatability (° maximum)0.0010.0010.0010.0010.001
Repeatability (° maximum)0.0010.0010.0020.0020.003

Electrical

Number of Axes1 or 2
Supply Voltage Range (VDC)36 to 57
Startup Voltage (VDC, Minimum)42
Noise (millidegrees rms, maximum)2
Input Current (mA, maximum)250
Input to Output Isolation (Vspeak Impulse)1500

Environmental

Operating Temperature Range-40°C to +85°C
Storage Temperature Range-40°C to +85°C
Vibration (grms)20
Shock1500g, 1 msec, ½ sine

Enclosure

Housing MaterialAnodized & Alodine Aluminum
Protection Class (per IEC 529)IP65
NEMA Enclosure Rating6
SealMIL-STD-202, Method 112
Connector TypeAmphenol RJF72B00
Recommended Mating ConnectorAmphenol RJF6B

Digital Output

InterfaceEthernet 10Base-T or 100Base-TX (Auto-sensing)
ProtocolTCP/IP, UPD/IP, ARP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, AutoIP, and HTTP
Output RepDegrees

Notes:
1: Full range is defined as “from negative full input angle to positive full input angle”
2: Non-linearity is specified as deviation of output referenced to a best fit straight line, independent of misalignment.
3: In default condition without averaging enabled