DXI-100/200 (Rail) Digital Inclinometer

The Jewell DXI-100/200 Series single or dual digital inclinometer takes Jewellโ€™s highly accurate analog closed-loop sensor technology to the next level. The DXI-100/200 is available with either RS-422 or RS-485 (Standard) digital interfaces. With a variety of options, including metric mounting threads, a flanged base, and CENELEC/AREMA certified, this product is easily customized to suit your specific application.

CENELEC-CECC-Logo

arema_web

Additional Information

Dimensions 1.63 × 3.63 × 1.85 in
Features

โ€ข Digital output
โ€ข Resolution 0.001ยฐ
โ€ข Mechanical Shock 1500g 1msec ยฝ sine
โ€ข Industry Standard EIA RS485 and EIA RS422 output
โ€ข For use in high shock and vibration environments
โ€ข High Precision and Performance
โ€ข Low Noise

Applications

โ€ข Radar/Antenna Control
โ€ข Structural Monitoring
โ€ข Linear Acceleration/Deceleration Measuring
โ€ข Automatic Train Position Control
โ€ข Seismic Monitoring
โ€ข Platform Leveling

Market

, ,

Performance Specifications

Static/Dynamic

Input Range (ยฐ)ยฑ1.0ยฑ3.0ยฑ14.5ยฑ30.0ยฑ60.0
Non Linearity (%FRO max20.060.0250.020.020.03
Scale Factor Tolerance (% maximum)0.10.10.10.10.1
Scale Factor Temperature Sensitivity (PPM/ยฐC maximum)100100100100100
Output at 0ยฐ Tilt (ยฐ max)ยฑ0.01ยฑ0.01ยฑ0.05ยฑ0.05ยฑ0.05
0ยฐ Output Temperature Sensitivity (ยฐ/ยฐC, maximum)0.0050.0050.0050.0050.005
Bandwidth (-3dB, Hz, nominal)336303030
Transverse Axis Misalignment (ยฐ maximum)0.150.050.50.50.5
Resolution & Threshold (ยต)0.0010.0010.0010.0010.001
Power on Repeatability (ยฐ maximum)0.0010.0010.0010.0010.001
Repeatability (ยฐ maximum)0.0010.0010.0020.0020.003

Electrical

Number of Axes1 or 2
Supply Voltage Range (VDC)10 to 30
Noise (g rms, maximum)0.005
Input Current (mA, maximum)100

Environmental

Operating Temperature Range-40ยฐC to +85ยฐC
Storage Temperature Range-40ยฐC to +85ยฐC
Vibration (grms)20
Shock1500g, 1 msec, ยฝ sine

Enclosure

Housing MaterialAnodized & Alodine Aluminum
Protection Class (per IEC 529)IP67
NEMA Enclosure Rating6
SealMIL-STD-202, Method 112
Connector TypeMS27476Y10D35P
Recommended Mating ConnectorMS27473T10B35S

Digital Output

InterfaceEthernet 10Base-T or 100Base-TX (Auto-sensing)
ProtocolTCP/IP, UPD/IP, ARP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, AutoIP, and HTTP
Output RepDegrees

Notes:
2: Non-linearity is specified as the deviation of output referenced to a best fit straight line, independent of misalignment.
3: In default condition without averaging enabled
4: Default Baud Rate is 38400

Downloads

Datasheet
DX-100/200 Outline Drawing
DX-XX Flanged Base Outline Drawing
DX Quick Start Guide
DX User's Manual
Servo Sensors Manual
Download All