Additional Information
Weight | 3 oz |
---|---|
Dimensions | 2.60 × 1.10 × 1.24 in |
Features | • Bandwidths to 200 Hz |
Options | • Unipolar Output |
Applications | • Antenna Stabilization |
The Jewell ASB Series Angular Accelerometer is a general-purpose ±200 radian/second² to ±1000 radian/second² device for industrial, commercial and sensing requirements.
Weight | 3 oz |
---|---|
Dimensions | 2.60 × 1.10 × 1.24 in |
Features | • Bandwidths to 200 Hz |
Options | • Unipolar Output |
Applications | • Antenna Stabilization |
Performance
Input Range (rad/sec2)1 | ±200 | ±500 | ±1000 |
Full Range Output (FRO, Volts ±1.0%) | ±5.0 | ±5.0 | ±5.0 |
Non-linearity (%FRO maximum)2 | 0.50 | 0.20 | 0.10 |
Scale Factor (Volts/rad/sec2 nominal) | 0.025 | 0.010 | 0.005 |
Scale Factor Temp Sens (PPM/°C maximum) | 180 | 180 | 180 |
Bias (rad/sec2 maximum) | 1.0 | 4.0 | 4.0 |
Bias Temperature Sensor (rad/sec2/°C maximum) | 0.05 | 0.05 | 0.10 |
Output Impedance (Ω nominal) | 10.0k | 4.0k | 5.0k |
Natural Frequency (Hz nominal)3 | 70 | 100 | 120 |
Bandwidth (-3dB, Hz nominal) | 70 | 100 | 120 |
Input Axis Misalignment (° maximum) | 1.0 | 1.0 | 1.0 |
Resolution & Threshold (rad/sec2 maximum) | 0.005 | 0.005 | 0.005 |
Electrical
Input Voltage (VDC nominal)4 | ±12 to ±18 |
Input Current (mA nominal) | 10.0 |
Noise (mvrms maximum) | 5.0 |
Environmental
Operating Temperature Range | -55 to +95°C |
Survival Temperature Range | -65 to +105°C |
Shock | 100g, 0.011 second, ½ sine |
Seal | MIL-STD-202, Method 112 |
Notes:
1: Full range is defined as "from negative full input acceleration to positive full input acceleration."
2: Nonlinearity is specified as deviation of output referenced to a best fit straight line, independent of misalignment.
3: Output phase angle = -90°.
4: Unit Power connections can be easily adapted for operation from single-ended, floating power supplies of 24 to 36 Volts DC
Datasheet |