The 750-200 tiltmeter series is a rugged, shock and vibration resistant, dual-axis tilt sensor designed for geotechnical applications. It is available in a small, convenient package and offers the options of 0-5Vdc or 4-20mA output signals.
The Jewell Black Diamond Series inclinometer is a low cost, high precision tilt sensor designed with higher accuracy than comparable MEMS devices. It is meant for geotechnical monitoring applications including bridge sag and sway, deflection measurement, platform leveling and structural analysis.
Additional information
Weight
8.1 oz
Dimensions
3.63 × 2.03 × 2.1 in
Features
• ±1° to ±90° Input Full Range
• Micro Radian Resolution
• Available Internal Temp Sensor
• High Level 0-5 Vdc Output
• Superior 0° Output Stability over Temperature
• Low Impedance Output
Applications
• Radar/Antenna Control
• Weapons Platform Leveling
• Barge and Offshore Platform Control
• Deviation Surveys
• 2-Axis Machine Tool Leveling
• Bridge Structural Monitoring
• Seismic Monitoring
• Platform Leveling
• Lab Testing & Research
• Submersible Control Feedback
• Production/Manufacturing Process Equipment
A750-200: 0-5V
Performance Specifications
Static/Dynamic
Input Range (°)
±1
±3
±14.5
±30
±90
Full Range Output (VDC, FRO ±1%)1
0-5
0-5
0-5
0-5
0-5
Non-linearity (%FRO maximum)2
0.05
0.05
0.02
0.02
0.02
Scale Factor (Volts/g, nominal)
143.2
47.8
10.0
5.0
2.5
Scale Factor Temperature Sensitivity (PPM/°C maximum)
300
300
100
60
60
Bandwidth (-3dB, Hz, nominal)
0.5
2.0
15.0
20.0
30.0
Transverse Axis Misalignment (° maximum)
±0.25
±0.50
±0.50
±1.00
±1.00
0° Output (Volts, maximum)
±0.10
±0.04
±0.02
±0.02
±0.02
0° Output Temperature Sensitivity (Volts/°C maximum)
Notes:
1: Full Range is defined “from negative full input angle to positive full input angle.”
2: Nonlinearity is specified as deviation of output referenced to theoretical sine function value, independent of misalignment.
C750-200: 4-20mA
Performance Specifications
Static/Dynamic
Input Range (°)
±1
±3
±14.5
±30
±90
Full Range Output (mA ±1%)1
4-20
4-20
4-20
4-20
4-20
Non-linearity (%FRO maximum)2
0.05
0.05
0.03
0.03
0.04
Scale Factor (mA/g, nominal)
458.4
152.9
32
16
8
Scale Factor Temperature Sensitivity (PPM/°C maximum)
300
300
100
100
100
Bandwidth (-3dB, Hz, nominal)
0.5
2.0
15.0
20.0
30.0
Transverse Axis Misalignment (° maximum)
±0.25
±0.50
±0.50
±0.50
±0.50
0° Output (mA, nominal)
12 ±0.6
12 ±0.6
12 ±0.3
12 ±0.3
12 ±0.3
0° Output Temperature Sensitivity (mA/°C maximum)
0.024
0.009
0.002
0.001
0.001
Resolution & Threshold (µ maximum)
1
1
1
1
1
Electrical
Number of Axes
1
Input Voltage Range (VDC)
+20 to +30
Input Current (mA, maximum)
45
Noise (µrms, maximum)
0.01
Environmental & Enclosure
Operating Temperature Range
-40°C to +80°C
Storage Temperature Range
-60°C to +90°C
Vibration
20 grms
Shock
1000g, 1 msec, ½ sine
Seal
MIL-STD 202, Method 112
Notes:
1: Full Range is defined “from negative full input angle to positive full input angle.”
2: Nonlinearity is specified as deviation of output referenced to theoretical sine function value, independent of misalignment