Model 901 & 902 Clinometer

Model 901 (horizontal) and 902 (vertical) Uniaxial & Biaxial Clinometers accurately measure an angular position with the same performance as Model 900, but in a slim design for use where space is limited. High-gain, standard, and wide-angle versions are available, each with a different angular range. A901 and A902 (biaxial) use high-level voltage outputs to allow signals to be delivered over long cables. C901 and C902 – also referred to as ‘Tulip’ (uniaxial) are loop-powered, so measurements can be made using an economical 2-wire pair. These conveniently sized, low-cost units fit neatly into underwater pressure housings, well logging tools, drilling equipment, and many other devices.

 

 

Additional Information

Dimensions 4.05 × .92 × .62 in
Features

• Uniaxial and biaxial options
• ±2.5 VDC, 0-5VDC, or 4-20mA output options
• Measure rotations about two orthogonal axes
­• Vertical or horizontal design

Performance Specifications

A901 & A902: ±2.5 VDC or 0-5 VDC

High-GainStandardWide-Angle
Angular Range (°)±10±25±50
Resolution (°)10.0050.010.02
Repeatability (°)0.020.020.02
Scale Factor (°/V)241025
Non-linearity (%)312.57
Output Voltage (V)±2.5 or 0-5
Output Impedance (Ω)270, short circuit protected
ChannelsX-tilt, Y-tilt, Temperature
Kz Coefficient (°/C, typical)10-20 arcsec
Ks Coefficient (%/C, typical)0.03
Time Constant (seconds)0.15
Natural Frequency (Hz)10
Power±2.5 Output: +8 to +24VDC
0-5 Output: +10.5 to +26.5 VDC
7mA, 250mV ripple max, reverse polarity protected
Environmental-40°C to +85°C operating and storage
0-90% humidity
MaterialsGlass electrolytic sensor, fiberglass PCB

Notes:
1: Resolution calculated at 1mV
2: Linear scale factor calculated from BFSL through a calibration curve
3: Linearity calculated as max % deviation from BFSL. 0.05% linearity achievable using a polynomial

*Specifications subject to change without notice on account of continued development.

C901 & C902 'Tulip': 4-20mA

High-GainStandardWide-Angle
Angular Range (°)±10±25±50
Resolution (°)10.0050.010.02
Repeatability (°)0.010.020.04
Scale Factor (°/mA)21.253.1256.25
Non-linearity (%)312.57
Output Voltage (mA)4-20
ChannelsTilt, Thermistor
Kz Coefficient (°/C, typical)10-20 arcsec
Ks Coefficient (%/C, typical)0.03
Time Constant (seconds)0.15
Natural Frequency (Hz)10
Power(0.02 Ampere x R + 10 VDC) < Vs < 29 VDC
Environmental-40 to +85°C operation and storage
0-90% humidity
MaterialsGlass electrolytic sensor, fiberglass PCB

Notes:
1: Resolution calculated at .003mA
2: Linear scale factor calculated from BFSL through a calibration curve
3: Linearity calculated as max % deviation from BFSL. 0.05% linearity achievable using a polynomial

*Specifications subject to change without notice on account of continued development.

Downloads

A901 & A902 Datasheet
Tulip Datasheet
Outline Drawing

Click outside to hide the comparison bar
Compare
×