DXI-100/200 Digital Inclinometer

The Jewell DXI-100/200 Series single or dual digital inclinometer takes Jewell’s highly accurate analog closed-loop sensor technology to the next level. The DXI-100/200 is available with either RS-422 or RS-485 (Standard) digital interfaces. With a variety of options, including metric mounting threads, a flanged base, and CENELEC/AREMA certified, this product is easily customized to suit your specific application.

Additional Information

Dimensions 1.63 × 3.63 × 1.85 in
Features

• Digital output
• Resolution 0.001°
• Mechanical Shock 1500g 1msec ½ sine
• Industry Standard EIA RS485 and EIA RS422 output
• For use in high shock and vibration environments
• High Precision and Performance
• Low Noise

Applications

• Radar/Antenna Control
• Structural Monitoring
• Linear Acceleration/Deceleration Measuring
• Automatic Train Position Control
• Seismic Monitoring
• Platform Leveling

Market

, ,

Performance Specifications

Static/Dynamic

Input Range (°)±1.0±3.0±14.5±30.0±60.0
Non Linearity (%FRO max20.060.0250.020.020.03
Scale Factor Tolerance (% maximum)0.10.10.10.10.1
Scale Factor Temperature Sensitivity (PPM/°C maximum)100100100100100
Output at 0° Tilt (° max)±0.01±0.01±0.05±0.05±0.05
0° Output Temperature Sensitivity (°/°C, maximum)0.0050.0050.0050.0050.005
Bandwidth (-3dB, Hz, nominal)336303030
Transverse Axis Misalignment (° maximum)0.150.050.50.50.5
Resolution & Threshold (µ)0.0010.0010.0010.0010.001
Power on Repeatability (° maximum)0.0010.0010.0010.0010.001
Repeatability (° maximum)0.0010.0010.0020.0020.003

Electrical

Number of Axes1 or 2
Supply Voltage Range (VDC)10 to 30
Noise (g rms, maximum)0.005
Input Current (mA, maximum)100

Environmental

Operating Temperature Range-40°C to +85°C
Storage Temperature Range-40°C to +85°C
Vibration (grms)20
Shock1500g, 1 msec, ½ sine

Enclosure

Housing MaterialAnodized & Alodine Aluminum
Protection Class (per IEC 529)IP67
NEMA Enclosure Rating6
SealMIL-STD-202, Method 112
Connector TypeMS27476Y10D35P
Recommended Mating ConnectorMS27473T10B35S

Digital Output

InterfaceEthernet 10Base-T or 100Base-TX (Auto-sensing)
ProtocolTCP/IP, UPD/IP, ARP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, AutoIP, and HTTP
Output RepDegrees

Notes:
2: Non-linearity is specified as the deviation of output referenced to a best fit straight line, independent of misalignment.
3: In default condition without averaging enabled
4: Default Baud Rate is 38400

Downloads

Datasheet
DX-100 Outline Drawing
DX-200 Outline Drawing
DX-XX Flanged Base Outline Drawing
DX Quick Start Guide
DX User's Manual
Servo Sensors Manual
Download All

Click outside to hide the comparison bar
Compare
×