Additional Information
Weight | 48 oz |
---|---|
Dimensions | 6 × 6 × 4 in |
The model A601-2 Platform mount tiltmeter is designed for high precision tilt measurements. Units come with built-in micrometer leveling legs, for easy installation on any horizontal surface. The A601-2 also includes two switchable gains and two low-pass filter settings. Using an absolute gravity-referenced electrolytic sensor, the A601-2 delivers ultra-high sensitivity to <25 nrad with virtually zero long-term drift. Output is a stable ±8 DC voltage (±16 VDC differential). Rugged, reliable, and extremely accurate, the A601-2 is the preferred choice for volcano monitoring, high-precision geotechnical engineering, bridge deflection monitoring, precision metrology, radar platform leveling, and high-accuracy tilt monitoring applications worldwide.
Weight | 48 oz |
---|---|
Dimensions | 6 × 6 × 4 in |
Model A601-2A (High Gain) | Model A601-2B (Mid Range) | |
---|---|---|
Angular Range | High Gain: ±200 µradians (±0.0115°) Low Gain: ±2000 µradians (±0.115°) | High Gain: ±400 µradians (±0.0235°) Low Gain: ±4000 µradians (±0.235°) |
Scale Factor | High Gain: 25 nradian/mV Low Gain: 250 nradian/mV | High Gain: 50 nradian/mV Low Gain: 500 nradian/mV |
Non-linearity | 2.0% | 2.0% |
Resolution | <25 nradians | <50 nradians |
Time Constant | Filter on: 7.5 sec; Filter off 0.5 sec | |
Kz Temp Coefficient (°/C) | ±3 µradians/°C (typical) | |
Ks Temp Coefficient (%/°C) | 0.05%/°C (typical) | |
Output | ±8VDC (single ended); ±16VDC (differential) | |
Channels | X-tilt, Y-tilt, Temperature | |
Output Impedance | 270 Ω | |
Temperature Output | 0.1°C/mV typical (single ended; 0°C = 0mV) | |
Power | ±11 to ±15 VDC @ +11 and -6mA, 250 mV ripple max, reverse polarity protected | |
Environmental | -25 to +70°C operational; -30 to +100°C storage; IP50 Seal | |
Materials | Anodized and painted aluminum dome, Stainless Steel base and hardware |
Datasheet |
User Manual |
Outline Drawing |