D7300 Modbus TCP/IP Ethernet Thermocouple Input Module

$400.00

The D7300 thermocouple input module contains seven differential inputs for measuring thermocouple temperature sensors.  Eight different thermocouple sensors can be measured, including types J, K, T, E, R, S, B and C.  Each input channel can be programmed to measure any one of eight types.

The module performs all signal conditioning, cold junction compensation, a 16-bit analog to digital conversion, linearization and stores the temperature result in a 16-bit unsigned integer format. The unsigned integer values represent a percentage of the full scale temperature range.

The data values are transmitted to any supervisory host computer that supports the Modbus TCP ethernet protocol.  See the links to a Modbus scaling example and product documentation below.

Download Datasheet

Download Manual

The D7300 voltage input module can be mounted on a DIN-Rail using the MK-1 mounting kit.

Thermocouple Measurement Ranges:
[one_half]J= -200 to +760 °C
K= -150 to +1250 °C
T= -200 to +400 °C
E= -100 to +1000 °C [/one_half][one_half_last]B= 0 to +1820 °C
S= 0 to +1750 °C
R= 0 to +1750 °C
C= 0 to +2315 °C[/one_half_last]

Out of stock

Additional Information

Dimensions 7.14 × 4 × 1.5 in
Features

• 7CH Differential Thermocouple Input Module
• User-selectable analog input range per channel.
• RJ-45 10/100Mbps Ethernet interface.
• Modbus TCP/IP Ethernet Protocol.
• IP Address, Static or DHCP (Default).
• Differential Thermocouple Inputs.
• 500Vrms Analog Input Isolation.
• 16-bit analog input measurement resolution.
• Continuous self-calibration
• Programmable thermocouple input digital filters.
• Requires +10V to +30Vdc unregulated supply, 1.4W.
• Removable screw terminal plug connectors.
• CE marked.

Software

The D7300 modules are compatible with all commercial software programs and OPC servers that support the Modbus TCP/IP ethernet protocol. Commercials software programs from Wonderware, DreamReport, Indusoft, DAQFactory and Dasylab all support the Modbus TCP/IP ethernet protocol. OPC Servers from Kepware and MatrikonOPC support the Modbus TCP/IP ethernet protocol.

Applications

• Process monitoring and control
• Remote data logging to any host computer
• Product testing