D1300 Thermocouple Input Modules

$325.00

The D1300 series modules measure thermocouple temperature sensors. Thermocouples consist of two wires made from dissimilar metals. The wires normally are joined or bonded together at one end to create a junction. This junction of different metals generates a predictable voltage output with changes in temperature.

The D1300 thermocouple input modules use an isolated 15-bit analog to digital converter to measure the thermocouple output voltage, perform cold-junction compensation and linearize the digital data into scaled temperature values. The temperature values can be scaled in either degrees Celsius or Fahrenheit.

The D1300 thermocouple input modules include two discrete digital inputs and three open-collector digital outputs. Two of the digital outputs can also be programmed as HI/LO alarm outputs based on the thermocouple temperature.

The digital outputs can be used to control solid-state relays or annunciators and can be pulled up to +30Vdc and sink up to 30mA without damage. The discrete digital inputs contain internal pull up resistors and can accept +/-30Vdc signals without damage.ย  The discrete switching levels are <+1Vdc = logic โ€œ0โ€, >+3.5Vdc equals a Logic โ€œ1โ€.

The scaled temperature values are transmitted to a host computer via an RS-232 or RS-485 serial port.

Use the links below to download a D1000 Series Datasheet or Userโ€™s Manual.

Download Datasheet

Download Manual

The D1300 current input modules can be mounted on a DIN-Rail using the MK-1 mounting kit.

 

Thermocouple Measurement Ranges:
J= -200 to +760 ยฐC
K= -150 to +1250 ยฐC
T= -200 to +400 ยฐC
E= -100 to +1000 ยฐC
B= 0 to +1820 ยฐC
S= 0 to +1750 ยฐC
R= 0 to +1750 ยฐC
C= 0 to +2315 ยฐC

Additional Information

Dimensions 3.6 × 2.45 × 1.1 in
Specifications

โ€ข Types: J, K, T, E, R, S, B, C
โ€ข Accuracy (errors from all sources) from 0 to +40C ambient: +/-1deg C max (J,K,T,E types). +/-2.5 deg C max for (R,S,B,C types).
โ€ข Resolution: 1 degree (C or F).
โ€ข Common mode rejection: 100db at 50/60 Hz.
โ€ข User selectable degrees C or F scaling.
โ€ข Lead resistance effect: <20uV per 350 ohms.
โ€ข Input burnout protection to 250 VAC.
โ€ข Input impedance: 100 megohm min.
โ€ข Automatic cold junction compensation and linearization.
โ€ข Three open-collector digital outputs.
โ€ข Two digital inputs.
โ€ข Open thermocouple indication.
โ€ข One digital input/60 Hz events counter

Note: D1300M series does not contain Events Counter.

Protocol

DGH ASCII

Additional Features

Digital Inputs, Digital Outputs, Events Counter

Click outside to hide the comparison bar
Compare
×