Additional Information
Dimensions | 1.53 in |
---|---|
Features | • Standard 5 Hz Bandwidth Cutoff |
Applications | • Robotics Orientation |
The Jewell LCI Series flexure suspension servo inclinometer is a ±3° to ±90° device designed for low frequency tilt sensing applications. LCI units are characterized by excellent turn on repeatability and very low hysteresis.
Dimensions | 1.53 in |
---|---|
Features | • Standard 5 Hz Bandwidth Cutoff |
Applications | • Robotics Orientation |
Static/Dynamic
Input Range (°) | ±3.0 | ±5.0 | ±10.0 | ±14.5 | ±30.0 | ±90.0 |
Full Range Output (VDC, FRO ±5%)1 | ±5 | ±5 | ±5 | ±5 | ±5 | ±5 |
Non-linearity (%FRO max)2 | 0.05 | 0.05 | 0.05 | 0.02 | 0.02 | 0.05 |
Scale Factor (Volts/g, nominal) | 95.5 | 57.4 | 28.8 | 20.0 | 10.0 | 5.0 |
Scale Factor Temperature Sensitivity (PPM/°C maximum) | 100 | 100 | 100 | 100 | 100 | 100 |
Bandwidth (-3dB, Hz, nominal) | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 |
Transverse Axis Misalignment (° maximum) | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 |
0° Output Range (Volts) | ±0.1 | ±0.6 | ±0.075 | ±0.05 | ±0.05 | ±0.025 |
0° Output Temperature Sensitivity (Volts/°C, maximum) | 0.0048 | 0.0029 | 0.0014 | 0.0003 | 0.0003 | 0.0003 |
Resolution & Threshold (µradian)3 | 1 | 1 | 1 | 1 | 1 | 1 |
Electrical
Number of Axes | 1 |
Input Voltage Range (VDC) | ±12 to ±18 |
Input Current (mA, maximum) | 30 |
Output Impedance (Ω, nominal) | 100 |
Noise (Vrms, maximum) | 0.001 |
Environmental
Operating Temperature Range | -55°C to +85°C |
Storage Temperature Range | -60°C to +90°C |
Shock | 3 foot drop |
Seal | MIL-STD-202, Mtd. 112 |
Notes:
1: Full range is defined as “from negative full input angle to positive full input angle.” The Inclinometer output is proportional to the sine of the tilt angle.
2: Nonlinearity is specified as deviation of output referenced to theoretical sine function value, independent of misalignment.
Datasheet |
Outline Drawing |
Servo Sensors Manual |