Additional Information
Weight | 10 oz |
---|---|
Dimensions | 2.03 × 3.63 × 2.1 in |
Features | • ±1° to ±90° Input Full Range |
Applications | • Radar & Antenna Leveling |
The Jewell LCF-2330 Series Inclinometer is a dual axis version of the rugged, high accuracy LCF Series. The design of the LCF-2330 was optimized to provide the high accuracy and superior
repeatability of Jewell’s rugged, fluid damped, flexure suspension, servo technology in a small and convenient package for applications requiring a compact dual axis solution. With many options to choose from, including a flange base, metric threads, and temperature sensor, this product can be customized to suit your individual needs.
Weight | 10 oz |
---|---|
Dimensions | 2.03 × 3.63 × 2.1 in |
Features | • ±1° to ±90° Input Full Range |
Applications | • Radar & Antenna Leveling |
Static/Dynamic
Input Range (°) | ±3.0 | ±5.0 | ±14.5 | ±30.0 | ±90.0 |
Full Range Output (VDC, FRO ±5%)1 | ±5 | ±5 | ±5 | ±5 | ±5 |
Non-linearity (%FRO max)2 | 0.05 | 0.05 | 0.02 | 0.02 | 0.05 |
Scale Factor (Volts/g, nominal) | 286.5 | 95.54 | 20.0 | 10.0 | 5.0 |
Scale Factor Temperature Sensitivity (PPM/°C maximum) | 200 | 100 | 100 | 100 | 100 |
Bandwidth (-3dB, Hz, nominal) | 3.0 | 3.0 | 30.0 | 30.0 | 30.0 |
Transverse Axis Misalignment (° maximum) | 0.25 | 0.50 | 0.50 | 0.50 | 0.50 |
0° Output (Volts Range) | ±0.75 | ±0.25 | ±0.075 | ±0.05 | ±0.05 |
0° Output Temperature Sensitivity (Volts/°C maximum) | 0.015 | 0.005 | 0.001 | 0.0005 | 0.0003 |
Resolution & Threshold (µ)3 | 1 | 1 | 1 | 1 | 1 |
Electrical
Number of Axes | 2 |
Input Voltage Range (VDC) | ±12 to ±18 |
Input Current (mA, maximum) | 30 |
Noise (Vrms, maximum) | 0.002 |
Output Impedance (Ω, nominal) | 100 |
Environmental & Enclosure
Operating Temperature Range | -40°C to +80°C |
Storage Temperature Range | -60°C to +90°C |
Vibration | 20 grms |
Shock | 1000g, 1 msec, ½ sine |
Seal | IP65 |
Customization Options:
Notes:
1: Full Range is defined "from negative full input angle to positive full input angle."
2: Nonlinearity is specified as deviation of output referenced to theoretical sine function value, independent of misalignment.
Static/Dynamic
Input Range (°) | ±1.0 | ±3.0 | ±14.5 | ±30.0 | ±90.0 |
Full Range Output (mA ±1%)1 | 4-20 | 4-20 | 4-20 | 4-20 | 4-20 |
Non-linearity (%FRO max)2 | 0.05 | 0.05 | 0.02 | 0.03 | 0.04 |
Scale Factor (mA/g, nominal) | 458.4 | 152.9 | 31.95 | 16.0 | 8.0 |
Scale Factor Temperature Sensitivity (PPM/°C maximum) | 300 | 300 | 100 | 100 | 100 |
Bandwidth (-3dB, Hz, nominal) | 0.5 | 2 | 15 | 20 | 30 |
Transverse Axis Misalignment (° maximum) | ±0.50 | ±0.50 | ±0.50 | ±0.50 | ±0.50 |
0° Output (mA) | 12 ±0.6 | 12 ±0.6 | 12 ±0.3 | 12 ±0.3 | 12 ±0.3 |
0° Output Temperature Sensitivity (Volts/°C maximum) | 0.024 | 0.009 | 0.002 | 0.001 | 0.001 |
Resolution & Threshold (µ)3 | 1 | 1 | 1 | 1 | 1 |
Electrical
Number of Axes | 2 |
Input Voltage Range (VDC) | 20 to 30 |
Input Current (mA, maximum) | 90 |
Noise (Vrms, maximum) | 0.01 |
Environmental & Enclosure
Operating Temperature Range | -40°C to +80°C |
Survival Temperature Range | -60°C to +90°C |
Vibration | 20 grms |
Shock | 1000g, 1 msec, ½ sine |
Seal | IP65 |
Customization Options
Notes:
1: Full Range is defined "from negative full input angle to positive full input angle."
2: Nonlinearity is specified as deviation of output referenced to theoretical sine function value, independent of misalignment.