Dimensions | 3.75 × 2.88 × 3 in |
---|---|
Features | • Ranges Available from ±1° to ±90° |
Applications | • Antenna Leveling |
LCF-2000 Dual-Axis Analog Inclinometer
The Jewell LCF 2000 Series dual axis inclinometer is a rugged, high accuracy version of the LCF Series. It is available with a wide range of options including single ended input power, internal temperature sensor and 4-20mA.
Performance Specifications
Static/Dynamic
Input Range (°) | ±3.0 | ±5.0 | ±14.5 | ±30.0 | ±90.0 |
Full Range Output (VDC, FRO ±5%)1 | ±5 | ±5 | ±5 | ±5 | ±5 |
Non-linearity (%FRO max)2 | 0.05 | 0.05 | 0.02 | 0.02 | 0.05 |
Scale Factor (Volts/g, nominal) | 286.5 | 95.54 | 20.0 | 10.0 | 5.0 |
Scale Factor Temperature Sensitivity (PPM/°C maximum) | 200 | 100 | 100 | 100 | 100 |
Bandwidth (-3dB, Hz, nominal) | 3.0 | 3.0 | 30.0 | 30.0 | 30.0 |
Transverse Axis Misalignment (° maximum) | 0.25 | 0.50 | 0.50 | 0.50 | 0.50 |
0° Output (Volts Range) | ±0.75 | ±0.25 | ±0.075 | ±0.05 | ±0.05 |
0° Output Temperature Sensitivity (Volts/°C maximum) | 0.015 | 0.005 | 0.001 | 0.0005 | 0.0003 |
Resolution & Threshold (µ)3 | 1 | 1 | 1 | 1 | 1 |
Electrical
Number of Axes | 2 |
Input Voltage Range (VDC) | ±12 to ±18 |
Input Current (mA, maximum) | 30 |
Output Impedance (Ω, nominal) | 100 |
Noise (Vrms, maximum) | 0.002 |
Environmental
Operating Temperature Range | -40°C to +80°C |
Storage Temperature Range | -40°C to +90°C |
Shock | 1000g, 0.001 sec, ½ sine |
Seal | MIL-STD-202, Mtd. 112 |
Vibration | 20 grms |
Custom Capabilities:
-
- Unit Power Connections can be easily adapted for operations from single-ended, floating power supplies of 24 to 36 VDC
- Internal Temperature Sensor
- 4-20mA Output
Notes:
1: Full range is defined as “from negative full input angle to positive full input angle.” The Inclinometer output is proportional to the sine of the tilt angle.
2: Nonlinearity is specified as deviation of output referenced to theoretical sine function value, independent of misalignment.
Downloads
Datasheet |
Outline Drawing |