Weight | 13.8 oz |
---|---|
Dimensions | 3.75 × 2.88 × 3.63 in |
Features | • Digital output |
Applications | • Radar/Antenna Control |
eDXI-100/200 Single or Dual Axis Digital Inclinometer
The Jewell eDXI-100/200 Series is a single or dual digital inclinometer with the convenience of Ethernet output. With its power over ethernet capability, no power source is needed. Simply plug it in to your computer.
Performance Specifications
Static/Dynamic
Input Range (°) | ±1.0 | ±3.0 | ±14.5 | ±30.0 | ±60.0 |
Non-linearity (%FRO max)2 | 0.02 | 0.015 | 0.02 | 0.02 | 0.03 |
Scale Factor Tolerance (% maximum) | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
Scale Factor Temperature Sensitivity (PPM/°C maximum) | 100 | 100 | 100 | 100 | 100 |
Output at 0° Tilt (° max) | ±0.01 | ±0.01 | ±0.05 | ±0.05 | ±0.05 |
0° Output Temperature Sensitivity (°/°C, maximum) | 0.005 | 0.005 | 0.005 | 0.005 | 0.005 |
Bandwidth (-3dB, Hz, nominal)3 | 3 | 6 | 30 | 30 | 30 |
Transverse Axis Misalignment (° maximum) | 0.15 | 0.15 | 0.5 | 0.5 | 0.5 |
Resolution & Threshold (° maximum) | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 |
Power on Repeatability (° maximum) | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 |
Repeatability (° maximum) | 0.001 | 0.001 | 0.002 | 0.002 | 0.003 |
Electrical
Number of Axes | 1 or 2 |
Supply Voltage Range (VDC) | 36 to 57 |
Startup Voltage (VDC, Minimum) | 42 |
Noise (millidegrees rms, maximum) | 2 |
Input Current (mA, maximum) | 250 |
Input to Output Isolation (Vspeak Impulse) | 1500 |
Environmental
Operating Temperature Range | -40°C to +85°C |
Storage Temperature Range | -40°C to +85°C |
Vibration (grms) | 20 |
Shock | 1500g, 1 msec, ½ sine |
Enclosure
Housing Material | Anodized & Alodine Aluminum |
Protection Class (per IEC 529) | IP65 |
NEMA Enclosure Rating | 6 |
Seal | MIL-STD-202, Method 112 |
Connector Type | Amphenol RJF72B00 |
Recommended Mating Connector | Amphenol RJF6B |
Digital Output
Interface | Ethernet 10Base-T or 100Base-TX (Auto-sensing) |
Protocol | TCP/IP, UPD/IP, ARP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, AutoIP, and HTTP |
Output Rep | Degrees |
Notes:
1: Full range is defined as “from negative full input angle to positive full input angle”
2: Non-linearity is specified as deviation of output referenced to a best fit straight line, independent of misalignment.
3: In default condition without averaging enabled
Downloads
Datasheet |
Outline Drawing |